EB3050L - 50Amp Circuit Breaker

- 50 Amp
- 10k @ 240VAC
- 3 Pole
Purchase Options: Refurbished
EB3050L - 50Amp Circuit Breaker Description
EB3050L - 50Amp Circuit Breaker
If you’re working on an older electrical system, you already know this: finding the right replacement breaker isn’t about “new vs old”—it’s about fit, compatibility, and keeping your system operating the way it was originally designed. The EB3050L 50 Amp 3-Pole Type EB circuit breaker is built specifically for that purpose.
Inside, the EB3050L uses a thermal-magnetic trip mechanism, which responds to both overload conditions and short-circuit events. That combination of protection has been widely used in electrical distribution systems for decades, and it remains a dependable method for safeguarding circuits in properly maintained equipment.
Because this is a non-interchangeable trip unit, it maintains the original design integrity of compatible Type EB panels. That’s especially important when working with legacy systems where consistency and proper matching are critical for safe operation.
In the field, you’ll typically find this breaker used in older commercial buildings, industrial facilities, institutional campuses, and municipal infrastructure—anywhere electrical systems from earlier panel generations are still in service and being maintained rather than replaced.
Key Features and Benefits
- Built for Type EB panelboards manufactured before 1989
- 50 amp, 3-pole breaker for three-phase electrical systems
- Thermal-magnetic protection for overload and short-circuit conditions
- 240VAC rating with 10kA interrupting capacity
- Non-interchangeable trip design for proper system compatibility
- Includes line and load terminals for easier replacement work
- Designed for form, fit, and function in existing legacy panels
- Commonly used in maintenance and repair of older electrical systems
- Suitable for commercial, industrial, and institutional environments
- Built to last for long-term service in properly maintained equipment
Technical Specifications
-
Part Number: EB3050L
-
Type: EB
-
Amperage: 50 Amps
-
Poles: 3
-
Voltage Rating: 240VAC
-
Interrupting Capacity: 10kA A.I.C. @ 240VAC
-
Trip Type: Thermal-Magnetic
-
Trip Unit: Non-Interchangeable
-
Temperature Rating: 40°C (104°F)
-
Terminals: Line and Load Included
-
Dimensions: 4.13" W × 6.0" H × 3.38" D
-
Shipping Weight: Approx. 5.50 lbs
Material Compliance and Certifications
The EB3050L is intended for use in compatible Type EB electrical panelboards and should only be installed by qualified electrical personnel. Always confirm panel compatibility, voltage rating, and system requirements before installation. Proper installation helps ensure safe operation within the design limits of the equipment.
Where It Works Best
The EB3050L is a strong fit for environments where older electrical systems are still in operation and reliability depends on correct component matching, including:
- Legacy commercial electrical distribution systems
- Industrial facilities with older Type EB panelboards
- Institutional buildings such as schools and campuses
- Municipal and government infrastructure systems
- Maintenance and repair projects on pre-1989 panel installations
- Three-phase power distribution setups requiring a 50 amp breaker
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Eaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are NOT supplied by Eaton Corporation plc or its affiliates.
Specifications
- Width:4.13
- Height:6.0
- Depth:3.38
- Poles:3
- Amperes:50
- A.I.C. Rating & Volts:10k @ 240VAC
- Type:EB
- Approx Dimensions:4.13"W x 6.00"H x 3.38"D
- Additional Notes:Thermal-magnetic circuit breaker with non-interchangeable trip unit. 40°C rated. This item includes line and load terminals. This breaker was designed for panels that were manufactured before 1989
Returns are easy
You may return unused items within 30 days of delivery for a full refund.
FREE ground shipping on breaker orders over $100 and all other items with orders over $500.
Shipping charges are Prepaid and Allowed on UPS Ground orders for all other products on orders over $500.00, again only when shipping within the lower 48 continental United States, provided the product(s) can safely ship UPS Ground.
If the product cannot safely ship via UPS Ground, or is too heavy to ship UPS Ground, then the product will be shipped via freightliner at buyer's expense.
CIRCUIT BREAKER SUPERSTORE® offers one to five day delivery in the United States. The variation depends on the chosen shipping speed and the warehouse location for the product(s).
Same Day Shipping
We strive to ship out your items within one business day.
In rare circumstances, CIRCUIT BREAKER SUPERSTORE® may reserve up to 5 business days to complete shipment. Feel free to contact us if your order is time sensitive.
CIRCUIT BREAKER SUPERSTORE® provides a limited 1-year warranty on both new and reconditioned products. Rest assured, all products are authentic OEM (original equipment manufacturer).