EHB2030L - 30Amp Circuit Breaker


- 30 Amp
- 14k @ 480VAC
- 2 Pole
Purchase Options: Refurbished
EHB2030L - 30Amp Circuit Breaker Description
EHB2030L - 30Amp Circuit Breaker
The EHB2030L is a 2-pole, 30 Amp Type EHB thermal-magnetic circuit breaker designed as a form, fit, and functional replacement for compatible electrical distribution systems that utilize Type EHB breakers. Engineered for installation in electrical panels manufactured before 1989, this breaker provides both thermal overload and magnetic short-circuit protection to help safeguard connected equipment and branch circuits.
Whether you're performing scheduled maintenance, replacing a worn breaker, or servicing an existing facility, the EHB2030L delivers the ratings and configuration required for compatible Type EHB applications. Matching the original form, fit, and function helps maintain the intended operation of legacy panelboards without modifying the existing electrical system. This breaker is commonly used by electricians, maintenance professionals, commercial facilities, and industrial operations that continue to support older electrical equipment.
Key Features and Benefits
- Designed as a form, fit, and functional replacement for compatible Type EHB applications
- 2-pole, 30 Amp thermal-magnetic circuit breaker
- Provides thermal overload and magnetic short-circuit protection
- Non-interchangeable trip unit helps maintain the original factory trip characteristics
- Rated for operation in 40°C (104°F) ambient environments
- Includes both line and load terminals
- Designed for compatible electrical panels manufactured before 1989
- Built to last for continued use in compatible legacy electrical systems
Technical Specifications
-
Part Number: EHB2030L
-
Type: EHB
-
Product Type: Thermal-Magnetic Circuit Breaker
-
Poles: 2
-
Amperage: 30 Amps
-
Interrupting Rating: 14kA @ 480VAC
-
Trip Unit: Non-Interchangeable
-
Operating Temperature: 40°C (104°F)
-
Terminals: Line and Load Terminals Included
-
Panel Compatibility: Designed for panels manufactured before 1989
-
Dimensions:
- Width: 2.75 inches
- Height: 6.00 inches
- Depth: 3.38 inches
-
Approximate Shipping Weight: 4.00 lbs.
Material Compliance and Certifications
- Molded case thermal-magnetic circuit breaker
- Interrupting rating: 14kA at 480VAC
- Rated for operation in 40°C (104°F) ambient environments
- Factory-equipped with line and load terminals
- Designed for installation in compatible Type EHB electrical equipment
- Installation should be performed in accordance with applicable electrical codes and the equipment manufacturer's requirements
- Verify breaker type, amperage, voltage rating, pole configuration, terminal configuration, and panel compatibility before installation
Where It Works Best
The EHB2030L is intended for use in compatible commercial, industrial, and institutional electrical systems utilizing Type EHB panelboards and related equipment manufactured before 1989. It is well suited for preventative maintenance, repairs, and replacement projects where preserving the original equipment configuration is important.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Eaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Edison®, Edison Fuse®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are NOT supplied by Eaton Corporation plc or its affiliates.
Specifications
- Width:2.75
- Height:6.0
- Depth:3.38
- Poles:2
- Amperes:30
- A.I.C. Rating & Volts:14k @ 480VAC
- Type:EHB
- Approx Dimensions:2.75"W x 6.00"H x 3.38"D
- Additional Notes:Thermal-magnetic circuit breaker with non-interchangeable trip unit. 40°C rated. This item includes line and load terminals. This breaker was designed for panels that were manufactured before 1989
Returns are easy
You may return unused items within 30 days of delivery for a full refund.
FREE ground shipping on breaker orders over $100 and all other items with orders over $500.
Shipping charges are Prepaid and Allowed on UPS Ground orders for all other products on orders over $500.00, again only when shipping within the lower 48 continental United States, provided the product(s) can safely ship UPS Ground.
If the product cannot safely ship via UPS Ground, or is too heavy to ship UPS Ground, then the product will be shipped via freightliner at buyer's expense.
CIRCUIT BREAKER SUPERSTORE® offers one to five day delivery in the United States. The variation depends on the chosen shipping speed and the warehouse location for the product(s).
Same Day Shipping
We strive to ship out your items within one business day.
In rare circumstances, CIRCUIT BREAKER SUPERSTORE® may reserve up to 5 business days to complete shipment. Feel free to contact us if your order is time sensitive.
CIRCUIT BREAKER SUPERSTORE® provides a limited 1-year warranty on both new and reconditioned products. Rest assured, all products are authentic OEM (original equipment manufacturer).
