THKMA836600WL - 600Amp Circuit Breaker


- 600 Amp
- 25k @ 600VAC; 35k @ 480VAC; 65k @ 240VAC
- 3 Pole
Purchase Options:
THKMA836600WL - 600Amp Circuit Breaker Description
THKMA836600WL - 600 Amp Circuit Breaker
The THKMA836600WL is a 600 Amp, 3-pole molded case circuit breaker designed for use in your commercial and industrial electrical distribution systems requiring dependable overcurrent and short-circuit protection. Built on the THKM8 platform, this breaker features an interchangeable thermal magnetic trip unit with internal common trip operation, helping to protect your connected equipment and conductors by disconnecting all poles during an overcurrent or fault condition.
Configured as a cable-in/cable-out (lug-lug) breaker, the THKMA836600WL includes both line-side and load-side lugs, simplifying installation in a variety of switchboards, panelboards, and distribution equipment. Its HACR rating makes it suitable for heating, air conditioning, and refrigeration applications where properly rated circuit protection is required. Designed for demanding electrical environments, this breaker provides the form, fit, and functional characteristics needed for maintaining and servicing existing power distribution systems. Like many industrial molded case breakers of its class, it was built for long-term service and dependable operation when properly installed and maintained.
Key Features and Benefits
- 600 Amp Continuous Current Rating: 600 Amp continuous current rating.
- 3-Pole Configuration: 3-pole configuration for three-phase electrical systems.
- THKM8 Molded Case Circuit Breaker Design: THKM8 molded case circuit breaker design.
- Interchangeable Thermal Magnetic Trip Unit: Interchangeable thermal magnetic trip unit.
- Internal Common Trip Mechanism: Internal common trip mechanism for coordinated pole operation.
- Cable-In/Cable-Out Construction: Cable-in/cable-out (lug-lug) construction.
- Included Lugs: Includes both line-side and load-side lugs.
- HACR Rated: HACR rated for applicable HVAC and refrigeration installations.
- Protection: Provides overcurrent and short-circuit protection.
- Commercial and Industrial Applications: Suitable for commercial and industrial power distribution equipment.
- Service and Replacement Applications: Designed for service, maintenance, and replacement applications requiring matching ratings and configuration.
Technical Specifications
-
Part Number: THKMA836600WL
-
Type: THKM8
-
Poles: 3
-
Amperage Rating: 600A
-
Trip Unit: Interchangeable Thermal Magnetic
-
Trip Configuration: Internal Common Trip
-
Connection Type: Cable-In/Cable-Out (Lug-Lug)
-
Included Accessories: Line-Side and Load-Side Lugs
-
HACR Rated: Yes
-
Interrupting Rating:
- 25kA @ 600VAC
- 35kA @ 480VAC
- 65kA @ 240VAC
-
Dimensions:
- Height: 15.5 in.
- Width: 8.25 in.
- Depth: 5.5 in.
Material Compliance and Certifications
- HACR Rated: HACR Rated.
- Commercial and Industrial Use: Manufactured for use in commercial and industrial electrical distribution systems.
- Construction and Performance Requirements: Designed to meet applicable molded case circuit breaker construction and performance requirements for its product class.
- Installation Verification: Verify local code requirements and application-specific compliance before installation.
Where It Works Best
- Industrial facilities and manufacturing plants.
- Commercial buildings and large electrical distribution systems.
- HVAC and refrigeration equipment installations requiring HACR-rated protection.
- Switchboards and power distribution assemblies.
- Motor and feeder protection applications.
- Maintenance projects requiring a matching THKM8-frame circuit breaker.
- Existing electrical systems where form, fit, and functional compatibility are critical.
- With its 600-amp capacity, thermal magnetic protection, lug-lug configuration, and common-trip operation, the THKMA836600WL is well-suited for protecting high-capacity electrical circuits in demanding commercial and industrial environments.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
GE®, and ABB® are registered trademarks of General Electric Company and ABB Ltd., respectively. Products sold are surplus, used, or refurbished and are NOT supplied by General Electric Company or ABB Ltd., or their affiliates.
Specifications
- Width:8.25
- Height:15.5
- Depth:5.5
- Poles:3
- Amperes:600
- A.I.C. Rating & Volts:25k @ 600VAC; 35k @ 480VAC; 65k @ 240VAC
- Type:THKM8
- Approx Dimensions:8.25"W x 15.50"L x 5.50"D
- Additional Notes:Cable-in/Cable-out (Lug-Lug), HACR Rated, Industrial Molded Case Circuit Breaker with Interchangeable, Thermal Magnetic Trip Unit and Internal Common Trip. Includes Line and Load-Side Lugs
Returns are easy
You may return unused items within 30 days of delivery for a full refund.
FREE shipping on breaker orders over $100 and all other items with orders over $500.
CIRCUIT BREAKER SUPERSTORE® offers one to five day delivery in the United States. The variation depends on the chosen shipping speed and the warehouse location for the product(s).
Same Day Shipping
We strive to ship out your items within one business day.
In rare circumstances, CIRCUIT BREAKER SUPERSTORE® may reserve up to 5 business days to complete shipment. Feel free to contact us if your order is time sensitive.
CIRCUIT BREAKER SUPERSTORE® provides a limited 1-year warranty on both new and reconditioned products. Rest assured, all products are authentic OEM (original equipment manufacturer).