- 60 Amp
- 150k @ 480VAC; 200k @ 240VAC
- 3 Pole
Purchase Options:
THLC134060 - 60Amp Circuit Breaker Description
THLC134060 - 60 Amp Circuit Breaker
When dependable circuit protection is required in an existing electrical distribution system, the THLC134060 circuit breaker provides the ratings and Configuration needed to maintain safe operation. This 3-pole, 60-amp current-limiting circuit breaker is designed for your applications where proper fault protection and equipment continuity are essential. Featuring a non-interchangeable trip unit and included load-side lugs, it offers the form, fit, and functional characteristics needed for compatible replacement projects in commercial and industrial environments.
With interrupting ratings of 150kA at 480VAC and 200kA at 240VAC, the THLC134060 is built to help you protect electrical systems from the damaging effects of short circuits and overcurrent conditions. Its compact footprint allows it to fit into designated equipment while maintaining the performance characteristics expected from the THLC1 series. Whether you're replacing an existing breaker during scheduled maintenance or restoring an electrical system to service, this breaker is designed to provide dependable protection in demanding environments.
Electrical professionals appreciate components that install correctly and perform as intended. The THLC134060 is built with that goal in mind, delivering reliable circuit protection while helping keep critical electrical systems operating safely.
Key Features and Benefits
- 60 Amp Rating: For reliable overcurrent protection.
- 3-Pole Configuration: Designed for three-phase electrical systems.
- Current Limiting Design: Helps reduce the effects of high fault currents.
- Non-Interchangeable Trip Unit: Helps maintain proper breaker configuration.
- Load-Side Lugs Included: For convenient field installation.
- Compact Dimensions: Support installation in compatible equipment.
- Built to Last: For long-term service in commercial and industrial applications.
- Form, Fit, and Functional Replacement: For compatible existing systems.
Technical Specifications
- Part Number: THLC134060
- Type: THLC1
- Poles: 3
- Amperage: 60A
- A.I.C. Rating: 150kA @ 480VAC
- A.I.C. Rating: 200kA @ 240VAC
-
Dimensions:
- Height: 8.75 in.
- Width: 4.13 in.
- Depth: 4.19 in.
- Configuration: Unfused
- Trip Unit: Non-Interchangeable
- Included Accessories: Load-Side Lugs
Material Compliance and Certifications
- Industry Standards: Manufactured to meet applicable industry standards for circuit protection equipment.
- Safety and Installation Requirements: Designed for use in electrical systems requiring compliance with recognized safety practices and installation requirements.
- Qualified Installation: Suitable for installation by qualified electrical professionals in accordance with local electrical codes and regulations.
Where It Works Best
- The THLC134060 60A circuit breaker is well-suited for commercial, industrial, and institutional electrical systems that require a 3-pole current-limiting breaker with high interrupting capacity. It is commonly used in switchboards, panelboards, and power distribution equipment where maintaining compatibility with existing infrastructure is important. Its combination of current-limiting protection and high A.I.C. ratings makes it a practical choice for facilities that need dependable protection against overcurrent and fault conditions while keeping electrical systems operating safely.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
GE®, and ABB® are registered trademarks of General Electric Company and ABB Ltd., respectively. Products sold are surplus, used, or refurbished and are NOT supplied by General Electric Company or ABB Ltd., or their affiliates.
Specifications
- Width:4.13
- Height:8.75
- Depth:4.19
- Poles:3
- Amperes:60
- A.I.C. Rating & Volts:150k @ 480VAC; 200k @ 240VAC
- Type:THLC1
- Approx Dimensions:4.13"W x 8.75"L x 4.19"D
- Additional Notes:Unfused, Current Limiting Circuit Breaker with Non-Interchangeable Trip Unit. Includes Load-Side Lugs
Returns are easy
You may return unused items within 30 days of delivery for a full refund.
FREE shipping on breaker orders over $100 and all other items with orders over $500.
CIRCUIT BREAKER SUPERSTORE® offers one to five day delivery in the United States. The variation depends on the chosen shipping speed and the warehouse location for the product(s).
Same Day Shipping
We strive to ship out your items within one business day.
In rare circumstances, CIRCUIT BREAKER SUPERSTORE® may reserve up to 5 business days to complete shipment. Feel free to contact us if your order is time sensitive.
CIRCUIT BREAKER SUPERSTORE® provides a limited 1-year warranty on both new and reconditioned products. Rest assured, all products are authentic OEM (original equipment manufacturer).