THLC134125 - 125Amp Circuit Breaker

  • 125 Amp
  • 150k @ 480VAC; 200k @ 240VAC
  • 3 Pole
Circuit BreakersSKU: THLC134125 [NS]

Purchase Options:

THLC134125 - 125Amp Circuit Breaker Description

THLC134125 - 125 Amp Circuit Breaker

The THLC134125 is a 125-amp, 3-pole current limiting circuit breaker designed for use in your commercial and industrial power distribution systems requiring high interrupting capacity and dependable circuit protection. Built with a non-interchangeable trip unit, this unfused breaker helps you to protect electrical equipment and conductors from damage caused by overloads and short circuits while maintaining compatibility with systems designed for Type THLC1 circuit breakers. Its current-limiting design helps reduce the amount of fault energy that passes through the electrical system during short-circuit events. The breaker includes load-side lugs for straightforward installation and is engineered for long service life in demanding electrical environments. Designed to meet the original form, fit, and function requirements of compatible installations, the THLC134125 remains a practical solution for maintaining and servicing existing electrical distribution equipment.

Key Features and Benefits

  • 125 amp current rating for commercial and industrial applications
  • 3-pole configuration for three-phase electrical systems
  • Type THLC1 circuit breaker design
  • Current-limiting construction helps reduce fault energy during short-circuit conditions
  • Non-interchangeable trip unit maintains consistent protection characteristics
  • Unfused design for applications requiring circuit breaker-based protection
  • Includes load-side lugs for installation convenience
  • High interrupting capacity rated at 150kAIC at 480VAC and 200kAIC at 240VAC
  • Designed to match the form, fit, and function requirements of compatible equipment
  • Built for long-term operation in demanding power distribution environments

Technical Specifications

  • Manufacturer Part Number: THLC134125
  • Type: THLC1
  • Poles: 3
  • Amperes: 125A
  • Voltage Rating: 240VAC / 480VAC
  • Interrupting Capacity: 150kA @ 480VAC; 200kA @ 240VAC
  • Trip Unit: Non-Interchangeable
  • Circuit Breaker Style: Current Limiting
  • Fuse Type: Unfused
  • Included Accessories: Load-Side Lugs
  • Dimensions:
    • Height: 8.75 in.
    • Width: 4.13 in.
    • Depth: 4.19 in.

Material Compliance and Certifications

  • Industry Standards: The THLC134125 is manufactured and rated for use in electrical distribution systems in accordance with applicable industry standards associated with its design and ratings.
  • Installation Requirements: Users should verify all installation requirements, certifications, and code compliance details for their specific application and jurisdiction prior to installation.

Where It Works Best

  • The THLC134125 is commonly used in commercial buildings, manufacturing facilities, institutional properties, and industrial power distribution systems where a 125-amp, 3-pole current limiting circuit breaker with high interrupting capacity is required. It is particularly well-suited for maintaining existing switchgear, panelboard, and distribution equipment designed to accept Type THLC1 breakers, making it a practical choice when preserving compatibility within established electrical systems.

Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.

GE®, and ABB® are registered trademarks of General Electric Company and ABB Ltd., respectively. Products sold are surplus, used, or refurbished and are NOT supplied by General Electric Company or ABB Ltd., or their affiliates.

Specifications

  • Width:4.13
  • Height:8.75
  • Depth:4.19
  • Poles:3
  • Amperes:125
  • A.I.C. Rating & Volts:150k @ 480VAC; 200k @ 240VAC
  • Type:THLC1
  • Approx Dimensions:4.13"W x 8.75"L x 4.19"D
  • Additional Notes:Unfused, Current Limiting Circuit Breaker with Non-Interchangeable Trip Unit. Includes Load-Side Lugs

Returns are easy

You may return unused items within 30 days of delivery for a full refund.

FREE shipping on breaker orders over $100 and all other items with orders over $500.

CIRCUIT BREAKER SUPERSTORE® offers one to five day delivery in the United States. The variation depends on the chosen shipping speed and the warehouse location for the product(s).

Same Day Shipping

We strive to ship out your items within one business day.

In rare circumstances, CIRCUIT BREAKER SUPERSTORE® may reserve up to 5 business days to complete shipment. Feel free to contact us if your order is time sensitive.

CIRCUIT BREAKER SUPERSTORE® provides a limited 1-year warranty on both new and reconditioned products. Rest assured, all products are authentic OEM (original equipment manufacturer).

Similar Products

Why Us?

Free Shipping

Free shipping on orders over $100

100k+ Happy Customers

4.9 Google rating

Secure Shopping

Feel protected with every transaction