THLC234125WL - 125Amp Circuit Breaker


- 125 Amp
- 150k @ 480VAC; 200k @ 240VAC
- 3 Pole
Purchase Options:
THLC234125WL - 125Amp Circuit Breaker Description
THLC234125WL - 125 Amp Circuit Breaker
The THLC234125WL is a 125-amp, 3-pole current limiting circuit breaker designed for use in your commercial and industrial power distribution systems where dependable circuit protection is essential. As part of the THLC2 series, this unfused breaker features a non-interchangeable trip unit. It is engineered to help you protect electrical equipment and conductors from damage caused by overcurrent conditions. Built for long-term service, the THLC234125WL combines a compact footprint with high interrupting capacity, making it well-suited for applications where available fault current levels demand reliable protection. This circuit breaker includes both line-side and load-side lugs, simplifying installation and helping you ensure secure electrical connections. With interrupting ratings of 150kA at 480VAC and 200kA at 240VAC, the THLC234125WL is commonly utilized in switchgear, distribution equipment, and other power system applications requiring a current-limiting solution. Its form, fit, and function make it a practical replacement option for compatible existing installations where maintaining system specifications is important.
Key Features and Benefits
- 125 Amp current rating: For commercial and industrial power distribution applications
- 3-pole configuration: For three-phase electrical systems
- Current limiting design: Helps reduce the effects of high fault currents
- Non-interchangeable trip unit: Provides fixed protective characteristics
- Includes both line-side and load-side lugs: For installation convenience
- High interrupting capacity: Rated at 150kA @ 480VAC and 200kA @ 240VAC
- Compact construction: Helps maximize available panel or switchgear space
- Designed for long service life: In demanding electrical environments
- Suitable as a form, fit, and function replacement: In compatible THLC2 applications
Technical Specifications
- Part Number: THLC234125WL
- Type: THLC2
- Circuit Breaker Type: Current Limiting, Unfused
- Poles: 3
- Amperage Rating: 125A
- Trip Unit: Non-Interchangeable
- Interrupting Rating: 150kA @ 480VAC
- Interrupting Rating: 200kA @ 240VAC
- Included Accessories: Line-Side and Load-Side Lugs
- Height: 11.44 in.
- Width: 5.72 in.
- Depth: 4.88 in.
Material Compliance and Certifications
- Compliance: The THLC234125WL is manufactured for use in electrical distribution systems requiring compliance with applicable industry standards and installation practices. Final compliance, certification requirements, and application suitability should always be verified against equipment specifications, local electrical codes, and project requirements before installation.
Where It Works Best
- Switchgear assemblies
- Power distribution equipment
- Industrial facilities
- Manufacturing plants
- Commercial buildings
- Utility and infrastructure projects
- Electrical systems with high available fault current levels
- Maintenance and replacement projects requiring compatibility with existing THLC2 installations
- When dependable overcurrent protection and high interrupting capacity are required, the THLC234125WL provides a practical solution for maintaining the safety and operation of electrical distribution systems.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
GE®, and ABB® are registered trademarks of General Electric Company and ABB Ltd., respectively. Products sold are surplus, used, or refurbished and are NOT supplied by General Electric Company or ABB Ltd., or their affiliates.
Specifications
- Width:5.72
- Height:11.44
- Depth:4.88
- Poles:3
- Amperes:125
- A.I.C. Rating & Volts:150k @ 480VAC; 200k @ 240VAC
- Type:THLC2
- Approx Dimensions:5.72"W x 11.44"L x 4.88"D
- Additional Notes:Unfused, Current Limiting Circuit Breaker with Non-Interchangeable Trip Unit. Includes Line and Load-Side Lugs
Returns are easy
You may return unused items within 30 days of delivery for a full refund.
FREE shipping on breaker orders over $100 and all other items with orders over $500.
CIRCUIT BREAKER SUPERSTORE® offers one to five day delivery in the United States. The variation depends on the chosen shipping speed and the warehouse location for the product(s).
Same Day Shipping
We strive to ship out your items within one business day.
In rare circumstances, CIRCUIT BREAKER SUPERSTORE® may reserve up to 5 business days to complete shipment. Feel free to contact us if your order is time sensitive.
CIRCUIT BREAKER SUPERSTORE® provides a limited 1-year warranty on both new and reconditioned products. Rest assured, all products are authentic OEM (original equipment manufacturer).